{"id":5839,"date":"2022-02-25T10:02:04","date_gmt":"2022-02-25T02:02:04","guid":{"rendered":"https:\/\/darksalmon-dugong-512221.hostingersite.com\/?p=5839"},"modified":"2022-02-25T10:02:08","modified_gmt":"2022-02-25T02:02:08","slug":"analysis-of-four-working-methods-of-ups-power-supply%ef%bf%bc","status":"publish","type":"post","link":"https:\/\/ygspower.com\/es\/analysis-of-four-working-methods-of-ups-power-supply%ef%bf%bc\/","title":{"rendered":"An\u00e1lisis de cuatro m\u00e9todos de funcionamiento de la fuente de alimentaci\u00f3n UPS"},"content":{"rendered":"<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><img fetchpriority=\"high\" decoding=\"async\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years-1024x560.jpg\" alt=\"\" class=\"wp-image-5841\" width=\"816\" height=\"446\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years-1024x560.jpg 1024w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years-600x328.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years-300x164.jpg 300w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years-768x420.jpg 768w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years-1536x840.jpg 1536w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/srchttp___www.qx100years.com_upload_at_image_20180423_1524478281954504Jxzr.jpgreferhttp___www.qx100years.jpg 1920w\" sizes=\"(max-width: 816px) 100vw, 816px\" \/><\/a><\/figure><\/div>\n\n\n\n<p><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>t\u00fa<\/strong><\/u><\/strong><strong><u><strong>PD<\/strong><\/u><\/strong><\/a>\u00a0es un voltaje constante y una frecuencia constante <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>sistema de alimentaci\u00f3n ininterrumpida<\/strong><\/u><\/strong><\/a>\u00a0con el dispositivo de almacenamiento de energ\u00eda y el inversor como componente principal. Su funci\u00f3n principal es suministrar energ\u00eda a los equipos electr\u00f3nicos de manera confiable e ininterrumpida a trav\u00e9s de la <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-ups-mu68b-battery-backup\/\"><strong><u><strong>Sistema UPS<\/strong><\/u><\/strong><\/a>Dependiendo del uso, el UPS se puede convertir a cuatro modos de funcionamiento diferentes: funcionamiento normal, funcionamiento con bater\u00eda, funcionamiento en bypass y mantenimiento en bypass.<\/p>\n\n\n\n<p>1. Modo de funcionamiento normal<\/p>\n\n\n\n<p>El <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-ups-mu68b-battery-backup\/\"><strong><u><strong>fuente de alimentaci\u00f3n<\/strong><\/u><\/strong><\/a>\u00a0El principio del sistema de alimentaci\u00f3n ininterrumpida es que cuando la red el\u00e9ctrica est\u00e1 normal, la m\u00e1quina convertir\u00e1 la corriente alterna de la red el\u00e9ctrica en corriente continua y luego cargar\u00e1 la <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>bater\u00eda<\/strong><\/u><\/strong><\/a>\u00a0para usar cuando se interrumpe la energ\u00eda; aqu\u00ed enfatizo que el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-ups-mu68b-battery-backup\/\"><strong><u><strong>sistema de alimentaci\u00f3n ininterrumpida<\/strong><\/u><\/strong><\/a>\u00a0No se trata solo de cuando se corta la energ\u00eda. Cuando el voltaje es demasiado bajo o demasiado alto, picos instant\u00e1neos, etc., que son suficientes para afectar la calidad de la energ\u00eda del funcionamiento normal del equipo, el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-ups-mu68b-battery-backup\/\"><strong><u><strong>sistema de alimentaci\u00f3n ininterrumpida<\/strong><\/u><\/strong><\/a>\u00a0El sistema funcionar\u00e1 para proporcionar energ\u00eda estable y limpia para el equipo.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><img decoding=\"async\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3.jpg\" alt=\"\" class=\"wp-image-5843\" width=\"646\" height=\"646\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3.jpg 1000w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3-300x300.jpg 300w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3-100x100.jpg 100w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3-600x600.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3-150x150.jpg 150w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-3-768x768.jpg 768w\" sizes=\"(max-width: 646px) 100vw, 646px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>Cuando la fuente de alimentaci\u00f3n principal se suministra normalmente, la red el\u00e9ctrica se divide en dos bucles para actuar simult\u00e1neamente despu\u00e9s del circuito de filtro. Uno es para cargar el paquete de bater\u00edas a trav\u00e9s del circuito de carga, y el otro es para pasar a trav\u00e9s del circuito rectificador como entrada del inversor, y luego pasar a trav\u00e9s del circuito rectificador. La conversi\u00f3n del inversor proporciona energ\u00eda a la carga; se puede ver que la salida del circuito en l\u00ednea <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-dc-ups-battery-backup-mu26-19-24wh-5200mah\/\"><strong><u><strong>sistema de alimentaci\u00f3n ininterrumpida<\/strong><\/u><\/strong><\/a>\u00a0es completamente alimentada por el inversor, por lo que independientemente de la calidad de la red el\u00e9ctrica, la salida es estable y no se ve afectada.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><img decoding=\"async\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/W-mini-ups3.jpg\" alt=\"\" class=\"wp-image-5846\" width=\"580\" height=\"580\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/W-mini-ups3.jpg 750w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/W-mini-ups3-300x300.jpg 300w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/W-mini-ups3-100x100.jpg 100w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/W-mini-ups3-600x600.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/W-mini-ups3-150x150.jpg 150w\" sizes=\"(max-width: 580px) 100vw, 580px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>2. C\u00f3mo funciona la bater\u00eda<\/p>\n\n\n\n<p>Cuando la red el\u00e9ctrica deja de funcionar correctamente, la corriente continua (CC) almacenada en la bater\u00eda se convierte en corriente alterna (CA). En este momento, la entrada del inversor es suministrada por el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>Paquete de bater\u00eda<\/strong><\/u><\/strong><\/a>, y el inversor contin\u00faa suministrando energ\u00eda para que la carga contin\u00fae us\u00e1ndola, de modo de lograr la funci\u00f3n de suministro de energ\u00eda ininterrumpido. La fuente de energ\u00eda del sistema de energ\u00eda ininterrumpida es la bater\u00eda, y la capacidad de la bater\u00eda es limitada, por lo que <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>sistema de alimentaci\u00f3n ininterrumpida<\/strong><\/u><\/strong><\/a>\u00a0No suministra energ\u00eda ilimitada como la red el\u00e9ctrica. El tiempo de suministro de energ\u00eda debe ser limitado. Para prolongar el tiempo de descarga, se debe comprar un SAI de larga duraci\u00f3n.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7.jpg\" alt=\"\" class=\"wp-image-5844\" width=\"654\" height=\"654\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7.jpg 1000w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7-300x300.jpg 300w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7-100x100.jpg 100w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7-600x600.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7-150x150.jpg 150w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/mu68-mini-ups-7-768x768.jpg 768w\" sizes=\"(max-width: 654px) 100vw, 654px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>3. Modo de operaci\u00f3n bypass<\/p>\n\n\n\n<p>Cuando el online <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-dc-ups-battery-backup-mu26-19-24wh-5200mah\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0est\u00e1 sobrecargado, el comando de bypass (manual o autom\u00e1tico), el inversor est\u00e1 sobrecalentado o la m\u00e1quina est\u00e1 averiada, el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0Generalmente convierte la salida del inversor en salida bypass, es decir, alimentada directamente por la red el\u00e9ctrica. Dado que la fase de la frecuencia de salida del inversor <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-dc-ups-battery-backup-mu26-19-24wh-5200mah\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0Debe ser la misma que la fase de la frecuencia de la red durante la derivaci\u00f3n. Se adopta la tecnolog\u00eda de sincronizaci\u00f3n de bloqueo de fase para garantizar que la salida del SAI est\u00e9 sincronizada con la red. El tiristor bidireccional del interruptor de derivaci\u00f3n funciona en paralelo, lo que resuelve el problema del tiempo de conmutaci\u00f3n de la derivaci\u00f3n y realmente logra <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mini-dc-ups-battery-backup-mu26-19-24wh-5200mah\/\"><strong><u><strong>ininterrumpido<\/strong><\/u><\/strong><\/a>\u00a0El circuito de conmutaci\u00f3n y control es complejo. Generalmente se utiliza en potencias medias y altas. <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>. En caso de sobrecarga, la carga debe reducirse artificialmente, de lo contrario, el disyuntor de derivaci\u00f3n cortar\u00e1 autom\u00e1ticamente la salida.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/Mini-DC-ups_01-1.jpg\" alt=\"\" class=\"wp-image-5845\" width=\"970\" height=\"424\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/Mini-DC-ups_01-1.jpg 750w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/Mini-DC-ups_01-1-600x262.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/02\/Mini-DC-ups_01-1-300x131.jpg 300w\" sizes=\"(max-width: 970px) 100vw, 970px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>4. M\u00e9todo de mantenimiento de bypass<\/p>\n\n\n\n<p>Cuando el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><u>\u00a0<\/u><\/a>se esta reparando, lo normal <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>fuente de alimentaci\u00f3n<\/strong><\/u><\/strong><\/a>\u00a0del equipo de carga se asegura mediante bypass manual. Una vez finalizada la operaci\u00f3n de mantenimiento, el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0se reinicia y el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mini-dc-ups-mu68w-12v-lithium-ion-battery-backup\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0Se convierte en una operaci\u00f3n normal. Tasa de mantenimiento extremadamente baja, MTTR de 150.000 horas, mejora en gran medida la disponibilidad del SAI.<\/p>","protected":false},"excerpt":{"rendered":"<p>Un SAI es un sistema de alimentaci\u00f3n ininterrumpida de tensi\u00f3n y frecuencia constantes que tiene como componentes principales el dispositivo de almacenamiento de energ\u00eda y el inversor. Su funci\u00f3n principal es suministrar energ\u00eda a equipos electr\u00f3nicos de forma fiable e ininterrumpida a trav\u00e9s del sistema SAI. Seg\u00fan el uso, el SAI puede configurarse en cuatro modos de funcionamiento diferentes: funcionamiento normal, funcionamiento con bater\u00eda [\u2026]<\/p>","protected":false},"author":5,"featured_media":5842,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Analysis of four working methods of UPS power supply","_seopress_titles_desc":"Analysis of four working methods of UPS power supply, mylion, mini dc ups, ups, battery pack, uninterrupted power supply, power supply, uninterruptible power system, ups system, ","_seopress_robots_index":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[35],"tags":[122,58,64,234,401,400,59,399],"class_list":["post-5839","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-battery-pack","tag-mini-dc-ups","tag-mylion","tag-power-supply","tag-uninterrupted-power-supply","tag-uninterruptible-power-system","tag-ups","tag-ups-system"],"_links":{"self":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/posts\/5839","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/comments?post=5839"}],"version-history":[{"count":0,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/posts\/5839\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/media\/5842"}],"wp:attachment":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/media?parent=5839"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/categories?post=5839"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/tags?post=5839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}