{"id":6454,"date":"2022-04-07T10:47:39","date_gmt":"2022-04-07T02:47:39","guid":{"rendered":"https:\/\/darksalmon-dugong-512221.hostingersite.com\/?p=6454"},"modified":"2022-04-07T10:47:43","modified_gmt":"2022-04-07T02:47:43","slug":"installation-and-design-requirements-of-large-ups-power-supply%ef%bf%bc","status":"publish","type":"post","link":"https:\/\/ygspower.com\/es\/installation-and-design-requirements-of-large-ups-power-supply%ef%bf%bc\/","title":{"rendered":"Requisitos de instalaci\u00f3n y dise\u00f1o de fuentes de alimentaci\u00f3n UPS de gran tama\u00f1o"},"content":{"rendered":"<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"750\" height=\"750\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-UPS.jpeg\" alt=\"\" class=\"wp-image-6458\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-UPS.jpeg 750w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-UPS-300x300.jpeg 300w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-UPS-100x100.jpeg 100w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-UPS-600x600.jpeg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-UPS-150x150.jpeg 150w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><figcaption>UPS tipo online 600VA-10KVA<\/figcaption><\/figure><\/div>\n\n\n\n<p>1. Requisitos para la gran escala <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-china-manufacturer-single-phase-off-line-ups-battery-ml650va-360w-simulated-sine-wave-offline-ups-for-computer\/\"><strong><u><strong>Fuente de alimentaci\u00f3n UPS<\/strong><\/u><\/strong><\/a>&nbsp;en el sitio y el medio ambiente<\/p>\n\n\n\n<p>(1) El lugar de instalaci\u00f3n del equipo debe ser un piso horizontal de cemento duro de tipo \u201cindustrial\u201d. Si se utiliza un piso elevado antiest\u00e1tico, debe dise\u00f1arse de acuerdo con el peso del SAI teniendo en cuenta la carga promedio del piso. Fabricar soportes de acero para montar el equipo.<\/p>\n\n\n\n<p>Para la mayor\u00eda de los proyectos a gran escala <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-simulated-sine-wave-ups-500va-300w-uninterruptible-power-supply-battery-backup-with-lifepo4-battery-ups-for-computer\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>, los cables del modelo est\u00e1ndar son del tipo de entrada y salida inferior. La entrada de aire de ventilaci\u00f3n del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw3ks-3kva-2700w-oline-ups-industrial-long-backup-time-ups-power-factor-high-frequency-online-ups-for-medical-equipment\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>&nbsp;El gabinete se encuentra en la parte frontal o lateral del gabinete, y la salida de aire se encuentra en la parte superior o trasera del gabinete. Por este motivo, antes de instalar el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw2ks-2kva-1800w-lithium-battery-backup-power-supply-online-ups-uninterrupted-power-supply-systems\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>, debemos verificar si el sitio del usuario cumple con las condiciones de instalaci\u00f3n. Si el usuario utiliza un tendido de cables en puente, el cable debe seleccionarse como el modelo de entrada y salida superior, y no est\u00e1 permitido ir al sitio y volver a perforar los orificios desde la caja del gabinete. , en este caso, provocar\u00e1 peligros ocultos para el equipo UPS.<\/p>\n\n\n\n<p>(2) El <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw10kl-10kva-9000w-lithium-battery-uninterrupted-power-supply-ups-systems-with-lcd-display\/\"><strong><u><strong>Sistema de suministro de energ\u00eda UPS<\/strong><\/u><\/strong><\/a>\u00a0Debe instalarse en un entorno operativo con suficiente ventilaci\u00f3n, frescor, baja humedad y aire limpio sin polvo. Aunque el rango de temperatura permitido por la normativa general <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw3ks-3kva-2700w-oline-ups-industrial-long-backup-time-ups-power-factor-high-frequency-online-ups-for-medical-equipment\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0La temperatura ambiente debe estar comprendida entre 0 \u00b0C y 40 \u00b0C. Sin embargo, si las condiciones lo permiten, la temperatura ambiente debe mantenerse por debajo de los 35 \u00b0C. Adem\u00e1s, no se deben almacenar elementos gaseosos o l\u00edquidos inflamables, explosivos o corrosivos en la habitaci\u00f3n donde funciona el SAI.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw3ks-3kva-2700w-oline-ups-industrial-long-backup-time-ups-power-factor-high-frequency-online-ups-for-medical-equipment\/\"><img decoding=\"async\" width=\"790\" height=\"834\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-type-UPS-5.jpg\" alt=\"\" class=\"wp-image-6459\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-type-UPS-5.jpg 790w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-type-UPS-5-600x633.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-type-UPS-5-284x300.jpg 284w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/Online-type-UPS-5-768x811.jpg 768w\" sizes=\"(max-width: 790px) 100vw, 790px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>(3) Est\u00e1 estrictamente prohibido instalar el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw10kl-10kva-9000w-lithium-battery-uninterrupted-power-supply-ups-systems-with-lcd-display\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>&nbsp;en un entorno de trabajo polvoriento con conductividad met\u00e1lica, de lo contrario se producir\u00e1 un cortocircuito en el equipo. Tampoco es recomendable colocar el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw2ks-2kva-1800w-lithium-battery-backup-power-supply-online-ups-uninterrupted-power-supply-systems\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>&nbsp;cerca de una fuente de calor.<\/p>\n\n\n\n<p>(4) Independientemente de si la <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><strong><u><strong>Paquete de bater\u00edas de UPS<\/strong><\/u><\/strong><\/a>&nbsp;Est\u00e1 equipado con un cargador con compensaci\u00f3n de temperatura. Para garantizar la vida \u00fatil del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><strong><u><strong>Paquete de bater\u00eda<\/strong><\/u><\/strong><\/a><strong>,<\/strong>&nbsp;La temperatura de la sala de bater\u00edas debe controlarse entre 20 \u00b0C y 25 \u00b0C.<\/p>\n\n\n\n<p>(5) De acuerdo con la forma del SAI, debe haber espacio para el mantenimiento al colocarlo. Algunos fabricantes de SAI<strong>&nbsp;<\/strong><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a><strong>&nbsp;<\/strong>Generalmente se requiere un espacio de 40-50 cm en los lados izquierdo y derecho, y al menos 50 cm en la parte posterior. Si se trata de un modelo de bajo consumo con ruedas, el espacio se puede reducir adecuadamente, pero se debe garantizar la refrigeraci\u00f3n y ventilaci\u00f3n del SAI.<\/p>\n\n\n\n<p>(6) Nota: Aunque requerimos la temperatura ambiente del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0La habitaci\u00f3n debe estar lo m\u00e1s baja posible, no podemos instalar el UPS o la bater\u00eda directamente debajo del aire acondicionado.<\/p>\n\n\n\n<p>(7) Para garantizar el funcionamiento fiable del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0y paquetes de bater\u00edas, est\u00e1 estrictamente prohibido colocar objetos diversos sobre la cubierta superior de los gabinetes del UPS y del paquete de bater\u00edas.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-simulated-sine-wave-ups-500va-300w-uninterruptible-power-supply-battery-backup-with-lifepo4-battery-ups-for-computer\/\"><img decoding=\"async\" width=\"750\" height=\"740\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-01.jpg\" alt=\"\" class=\"wp-image-6460\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-01.jpg 750w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-01-100x100.jpg 100w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-01-600x592.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-01-300x296.jpg 300w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/a><figcaption>SAI de 500 VA a 3000 VA<\/figcaption><\/figure><\/div>\n\n\n\n<p>2. Par\u00e1metros b\u00e1sicos de dise\u00f1o de instalaci\u00f3n que los usuarios deben tener en cuenta al momento de comprar <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw2ks-2kva-1800w-lithium-battery-backup-power-supply-online-ups-uninterrupted-power-supply-systems\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a><\/p>\n\n\n\n<p>Debido a la carga del usuario y al factor de potencia del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-high-frequency-single-phase-online-ups-mw1ks-1kva-900w-ups-backup\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>, el SAI seleccionado por el cliente general tiene b\u00e1sicamente un cierto margen de potencia. Debemos determinar el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-online-ups-mw6ks-6kva-5400w-lcd-ups-battery-backup-for-medical-equipment-ups-power-supply\/\"><strong><u><strong>fuente de alimentaci\u00f3n<\/strong><\/u><\/strong><\/a>\u00a0de la sala de ordenadores y la potencia requerida seg\u00fan la potencia del SAI y del pack de bater\u00edas. Di\u00e1metro del cable, ya que el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/600va-360w-online-ups-pure-sine-wave-battery-backup-for-computer\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0y el paquete de bater\u00edas generalmente se instalan en interiores, el extremo de entrada de CA del SAI estar\u00e1 cerca del tablero de distribuci\u00f3n del usuario. Si la energ\u00eda de la red el\u00e9ctrica del usuario que llega a la sala de computadoras es mucho mayor que la energ\u00eda del SAI, el di\u00e1metro del cable de entrada del SAI puede ser Seg\u00fan la configuraci\u00f3n general del cable de corta distancia, el cable del cable con n\u00facleo de cobre de corta distancia generalmente puede soportar una corriente de 4,5 A por secci\u00f3n cuadrada. Al configurar el cable, tambi\u00e9n debemos agregar la energ\u00eda real utilizada y la energ\u00eda del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-new-design-poe-uninterruptible-power-supply-dc-48v-65wh-17600mah-ups-lcd-display-long-life-emergency-backup-ups\/\"><strong><u><strong>bater\u00eda<\/strong><\/u><\/strong><\/a>\u00a0Carga flotante para configurar el cable adecuado. Si la potencia de entrada del cuadro el\u00e9ctrico del usuario no puede satisfacer los requisitos de suministro de energ\u00eda del SAI, para garantizar el uso normal del mismo <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw3ks-3kva-2700w-oline-ups-industrial-long-backup-time-ups-power-factor-high-frequency-online-ups-for-medical-equipment\/\"><strong><u><strong>Sistema UPS<\/strong><\/u><\/strong><\/a>Debemos exigir al cliente que proporcione un entorno energ\u00e9tico que satisfaga el uso del equipo.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-china-manufacturer-single-phase-off-line-ups-battery-ml650va-360w-simulated-sine-wave-offline-ups-for-computer\/\"><img loading=\"lazy\" decoding=\"async\" width=\"732\" height=\"1024\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-05-732x1024.jpg\" alt=\"\" class=\"wp-image-6461\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-05-732x1024.jpg 732w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-05-600x839.jpg 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-05-214x300.jpg 214w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/ups-05.jpg 750w\" sizes=\"(max-width: 732px) 100vw, 732px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>Se entiende que la conexi\u00f3n entre la <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/600va-360w-online-ups-pure-sine-wave-battery-backup-for-computer\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>&nbsp;y la bater\u00eda generalmente la completa el proveedor del SAI. Debemos determinar la l\u00ednea de conexi\u00f3n del paquete de bater\u00edas seg\u00fan la potencia del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-new-design-poe-uninterruptible-power-supply-dc-48v-65wh-17600mah-ups-lcd-display-long-life-emergency-backup-ups\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>&nbsp;y el tiempo de respaldo de configuraci\u00f3n del SAI. Una configuraci\u00f3n razonable puede garantizar la confiabilidad del sistema de suministro de energ\u00eda del SAI. Generalmente, la corriente de descarga de la bater\u00eda proh\u00edbe la descarga a largo plazo a una tasa de descarga de m\u00e1s de 3C. Por lo tanto, cuando configuramos el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/600va-360w-online-ups-pure-sine-wave-battery-backup-for-computer\/\"><strong><u><strong>bater\u00eda<\/strong><\/u><\/strong><\/a>, debemos configurar la bater\u00eda de manera razonable de acuerdo con la corriente de descarga m\u00e1xima del paquete de bater\u00edas en el <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-mw2ks-2kva-1800w-lithium-battery-backup-power-supply-online-ups-uninterrupted-power-supply-systems\/\"><strong><u><strong>Sistema UPS<\/strong><\/u><\/strong><\/a>.<\/p>\n\n\n\n<p>Para los diferentes tipos de UPS, los requisitos para <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-high-frequency-single-phase-online-ups-mw1ks-1kva-900w-ups-backup\/\"><strong><u><strong>fuente de alimentaci\u00f3n<\/strong><\/u><\/strong><\/a>\u00a0Los cables tambi\u00e9n son diferentes. Por ejemplo, para un SAI de una determinada marca y serie A, como su alimentaci\u00f3n en bypass est\u00e1 conectada a la fase C de la red, instalamos la l\u00ednea de entrada de la fase C del SAI. <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-manufactured-high-quality-simulate-sine-wave-ups-ml500va-500va-300w-battery-backup-for-display-equipment\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0Durante la instalaci\u00f3n, generalmente se requiere que el di\u00e1metro sea m\u00e1s grueso que el di\u00e1metro de la fase de entrada A y B. Al mismo tiempo, debido al problema del entorno de la red el\u00e9ctrica actual, en el modo de cableado de entrada del sistema trif\u00e1sico de cinco cables, excepto que el di\u00e1metro del cable de conexi\u00f3n a tierra puede ser ligeramente m\u00e1s delgado, el cable neutro debe tener al menos Tambi\u00e9n debe tener el mismo di\u00e1metro que el cable de fase y debe engrosarse si es necesario. <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-manufactured-high-quality-simulate-sine-wave-ups-ml500va-500va-300w-battery-backup-for-display-equipment\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0de una determinada serie B de una empresa, debido a que la m\u00e1quina tiene tres entradas y tres salidas, el di\u00e1metro general del cable de entrada puede ser el mismo, excepto el cable de tierra que es ligeramente m\u00e1s delgado. El di\u00e1metro del cable de salida se puede ajustar adecuadamente de acuerdo con la carga real. A excepci\u00f3n del SAI con tres entradas y una salida, el di\u00e1metro del cable de salida del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/600va-360w-online-ups-pure-sine-wave-battery-backup-for-computer\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>\u00a0Generalmente es m\u00e1s peque\u00f1o que el di\u00e1metro del cable de entrada.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-new-design-poe-uninterruptible-power-supply-dc-48v-65wh-17600mah-ups-lcd-display-long-life-emergency-backup-ups\/\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/48vdc-ups-1_\u526f\u672c.jpg\" alt=\"\" class=\"wp-image-6462\" width=\"666\" height=\"830\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/48vdc-ups-1_\u526f\u672c.jpg 442w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/48vdc-ups-1_\u526f\u672c-240x300.jpg 240w\" sizes=\"(max-width: 666px) 100vw, 666px\" \/><\/a><figcaption>SAI de 48 V<\/figcaption><\/figure><\/div>\n\n\n\n<p>Si hay un generador en el lugar del usuario, la potencia y el rendimiento del generador deben cumplir con los requisitos del SAI. Por lo general, la potencia del generador es m\u00e1s de 4 o 5 veces la potencia del <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-new-design-poe-uninterruptible-power-supply-dc-48v-65wh-17600mah-ups-lcd-display-long-life-emergency-backup-ups\/\"><strong><u><strong>Uni\u00f3n Postal Universal<\/strong><\/u><\/strong><\/a>La calidad del generador no es buena. Debido a que la resistencia interna del generador es mucho mayor que la de la red el\u00e9ctrica, en el caso del SAI rectificador controlado por fase, puede parecer que el generador funciona de forma anormal cuando <a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-high-frequency-single-phase-online-ups-mw1ks-1kva-900w-ups-backup\/\"><strong><u><strong>Suministro de energ\u00eda<\/strong><\/u><\/strong><\/a>, lo que produce oscilaci\u00f3n.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/darksalmon-dugong-512221.hostingersite.com\/product\/mylion-new-design-poe-uninterruptible-power-supply-dc-48v-65wh-17600mah-ups-lcd-display-long-life-emergency-backup-ups\/\"><img loading=\"lazy\" decoding=\"async\" width=\"713\" height=\"837\" src=\"http:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/\u5fae\u4fe1\u56fe\u7247_20220407103938.png\" alt=\"\" class=\"wp-image-6463\" srcset=\"https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/\u5fae\u4fe1\u56fe\u7247_20220407103938.png 713w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/\u5fae\u4fe1\u56fe\u7247_20220407103938-600x704.png 600w, https:\/\/ygspower.com\/wp-content\/uploads\/2022\/04\/\u5fae\u4fe1\u56fe\u7247_20220407103938-256x300.png 256w\" sizes=\"(max-width: 713px) 100vw, 713px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>Enlace de UPS de Mylion: https:\/\/darksalmon-dugong-512221.hostingersite.com\/category\/other-products\/ups\/<\/p>","protected":false},"excerpt":{"rendered":"<p>1. Requisitos para el suministro de energ\u00eda de UPS a gran escala en el sitio y el entorno (1) El sitio de instalaci\u00f3n del equipo debe ser un piso horizontal de cemento duro de tipo \u201cindustrial\u201d. Si se utiliza un piso elevado antiest\u00e1tico, debe dise\u00f1arse de acuerdo con el peso del UPS teniendo en cuenta la carga promedio del piso. Aseg\u00farese de [\u2026]<\/p>","protected":false},"author":5,"featured_media":6457,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"none","_seopress_titles_title":"Installation and design requirements of large UPS power supply","_seopress_titles_desc":"Installation and design requirements of large UPS power supply, mylion, UPS, power supply, UPS power supply, large UPS, battery, UPS system, supplying power, requirements, UPS supplier,  battery packs","_seopress_robots_index":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[35],"tags":[49,270,569,64,234,570,571,59,167,572,399],"class_list":["post-6454","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-battery","tag-battery-packs","tag-large-ups","tag-mylion","tag-power-supply","tag-requirements","tag-supplying-power","tag-ups","tag-ups-power-supply","tag-ups-supplier","tag-ups-system"],"_links":{"self":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/posts\/6454","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/comments?post=6454"}],"version-history":[{"count":0,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/posts\/6454\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/media\/6457"}],"wp:attachment":[{"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/media?parent=6454"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/categories?post=6454"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ygspower.com\/es\/wp-json\/wp\/v2\/tags?post=6454"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}